Difference between revisions of "Roll-off"
m (→Higher order networks: remove italics from suffix) |
m (1 revision) |
(No difference)
|
Latest revision as of 13:49, 10 December 2011
- This article is about roll-off in electrical network analysis. For the dumpster, see roll-off (dumpster).
Roll-off is a term commonly used to describe the steepness of a transmission function with frequency, particularly in electrical network analysis, and most especially in connection with filter circuits in the transition between a passband and a stopband. It is most typically applied to the insertion loss of the network, but can in principle be applied to any relevant function of frequency, and any technology, not just electronics. It is usual to measure roll-off as a function of logarithmic frequency, consequently, the units of roll-off are either decibels per decade (dB/decade), where a decade is a 10-times increase in frequency, or decibels per octave (dB/8ve), where an octave is 2-times increase in frequency.
The concept of roll-off stems from the fact that in many networks roll-off tends towards a constant gradient at frequencies well away from the cut-off point of the frequency curve. Roll-off enables the cut-off performance of such a filter network to be reduced to a single number. Note that roll-off can occur with decreasing frequency as well as increasing frequency, depending on the bandform of the filter being considered: for instance a low-pass filter will roll-off with increasing frequency, but a high-pass filter or the lower stopband of a band-pass filter will roll-off with decreasing frequency. For brevity, this article describes only low-pass filters. This is to be taken in the spirit of prototype filters; the same principles may be applied to high-pass filters by interchanging phrases such as "above cut-off frequency" and "below cut-off frequency".
Contents
First order roll-off
A simple first order network such as a RC circuit will have a roll-off of 20 dB/decade. This is approximately equal (to within normal engineering required accuracy) to 6 dB/8ve and is the more usual description given for this roll-off. This can be shown to be so by considering the voltage transfer function, A, of the RC network:[1]
- <math>A=\frac{V_o}{V_i}=\frac{1}{1+i\omega RC}</math>
Frequency scaling this to ωc=1/RC=1 and forming the power ratio gives,
- <math>|A|^2=\frac{1}{1+\left( {\omega \over \omega_c} \right)^2} = \frac{1}{1+\omega^2}</math>
In decibels this becomes,
- <math>10\log \left({\frac{1}{1+\omega^2}}\right)</math>
or expressed as a loss,
- <math>L=10\log \left({1+\omega^2}\right) \ \mathrm{dB}</math>
At frequencies well above ω=1, this simplifies to,
- <math>L \approx 10\log \left(\omega^2\right)= 20\log \omega \ \mathrm{dB}</math>
Roll-off is given by,
- <math>\Delta L = 20\log \left( {\omega_2 \over \omega_1} \right) \ \mathrm{dB/interval_{2,1}}</math>
For a decade this is;
- <math>\Delta L = 20\log 10 = 20 \ \mathrm{dB/decade}</math>
and for an octave,
- <math>\Delta L = 20\log 2 \approx 20 \times 0.3 = 6 \ \mathrm{dB/8ve}</math>
Higher order networks
A higher order network can be constructed by cascading first-order sections together. If a unity gain buffer amplifier is placed between each section (or some other active topology is used) there is no interaction between the stages. In that circumstance, for n identical first-order sections in cascade, the voltage transfer function of the complete network is given by;[1]
- <math>A_{\mathrm T}=A^n \ </math>
consequently, the total roll-off is given by,
- <math>\Delta L_{\mathrm T} = n \Delta L = 6n \ \mathrm{dB/8ve}</math>
A similar effect can be achieved in the digital domain by repeatedly applying the same filtering algorithm to the signal.[2]
The calculation of transfer function becomes somewhat more complicated when the sections are not all identical, or when the popular ladder topology construction is used to realise the filter. In a ladder filter each section of the filter has an effect on its immediate neighbours and a lesser effect on more remote sections so the response is not a simple An even when all the sections are identical. For some filter classes, such as the Butterworth filter, the insertion loss is still monotonically increasing with frequency and quickly asymptotically converges to a roll-off of 6n dB/8ve, but in others, such as the Chebyshev or elliptic filter the roll-off near the cut-off frequency is much faster and elsewhere the response is anything but monotonic. Nevertheless, all filter classes eventually converge to a roll-off of 6n dB/8ve theoretically at some arbitrarily high frequency, but in many applications this will occur in a frequency band of no interest to the application and parasitic effects may well start to dominate long before this happens.[3]
Applications
Filters with a high roll-off were first developed to prevent crosstalk between adjacent channels on telephone FDM systems.[4] Roll-off is also significant on audio loudspeaker crossover filters: here the need is not so much for a high roll-off but that the roll-offs of the high frequency and low-frequency sections are symmetrical and complementary. An interesting need for high roll-off arises in EEG machines. Here the filters mostly make do with a basic 6 dB/8ve roll-off, however, some instruments provide a switchable 35 Hz filter at the high frequency end with a faster roll-off to help filter out noise generated by muscle activity.[5]
See also
Notes
Cite error: Invalid <references>
tag;
parameter "group" is allowed only.
<references />
, or <references group="..." />
References
- J. William Helton, Orlando Merino, Classical control using H [infinity] methods: an introduction to design, pages 23-25, Society for Industrial and Applied Mathematics 1998 ISBN 0898714249.
- Todd C. Handy, Event-related potentials: a methods handbook, pages 89-92, 107-109, MIT Press 2004 ISBN 0262083337.
- Fay S. Tyner, John Russell Knott, W. Brem Mayer (ed.), Fundamentals of EEG Technology: Basic concepts and methods, pages 101-102, Lippincott Williams & Wilkins 1983 ISBN 089004385X.