Doubly-fed electric machines are electric motors or electric generators that have windings on both stationary and rotating parts, where both windings transfer significant power between shaft and electrical system. Doubly-fed machines are useful in applications that require varying speed of the machine's shaft for a fixed power system frequency.

Classification

Electric machines are either Singly-Fed with one winding set that actively participates in the energy conversion process or Doubly-Fed with two active winding sets. The wound-rotor induction machine and the field-excited synchronous machine are singly-fed machines because only one winding set actively participates in the energy conversion process.

Examples of doubly-fed electric machines are the wound-rotor doubly-fed electric machine, the brushless wound-rotor doubly-fed electric machine, and the brushless doubly-fed induction electric machines.

Features of doubly fed machines

The wound-rotor doubly-fed electric machine is the only electric machine that operates with rated torque to twice synchronous speed for a given frequency of excitation (i.e., 7200 rpm @ 60 Hz and one pole-pair versus 3600 rpm for singly-fed electric machines). Higher speed with a given frequency of excitation gives lower cost, higher efficiency, and higher power density. In concept, any electric machine can be converted to a wound-rotor doubly-fed electric motor or generator by changing the rotor assembly to a multiphase wound rotor assembly of equal stator winding set rating. If the rotor winding set can transfer power to the electrical system, the conversion result is a wound-rotor doubly-fed electric motor or generator with twice the speed and power as the original singly-fed electric machine. The resulting dual-ported transformer circuit topology allows very high torque current without core saturation, all by electronically controlling half or less of the total motor power for full variable speed control.

In practice, the classical wound-rotor doubly-fed "induction" electric motor or generator system has known issues of instability, high maintenance and inefficiency of an integral multiphase slip-ring assembly, and discontinuity about synchronous speed where induction ceases to exist. A practical wound-rotor doubly-fed electric machine system that does not rely exclusively on asynchronous (i.e., induction) principles while symmetrically motoring or generating over its entire speed range has never materialized from the electric machine establishment, despite years of research to find an evolutionary brushless, synchronous, and stable control technology. Consequently, the wound-rotor doubly-fed induction electric machine has been forced into antiquity, except in large installations where efficiency and cost are critical over a limited speed range, such as wind turbines. This may change with recent Brushless Wound-Rotor Doubly-Fed Electric Machine technology development.

As do all electromagnetic electric machines, doubly fed machines need torque current to produce the torque. Because there are no permanent magnets in the doubly fed machine, magnetizing current is also needed to produce magnetic flux. Magnetizing current and torque current are orthogonal vectors and do not add directly. Since the magnetizing current is much smaller than the torque current, it is only significant in the efficiency of the machine at very low torque. Like wound rotor synchronous machines, the magnetic flux can be produced by the stator current, rotor current or by the combination of the both. For example, if all manetizing current is supplied by the rotor windings, the stator will only have torque curernt and so unity power factor. At synchronous speed the rotor current has to be DC, as in ordinary synchronous machines. If the shaft speed is above or below synchronous speed, the rotor current must be AC at the slip frequency. Reactive power is used in the rotor winding when it is used to magnetize the machine in non-synchronous operation.

Rotor current is also needed to produce torque in addition to magnetization. Thus active power is present in the rotor in addition to reactive power.

The frequency and the magnitude of the rotor voltage is proportional to the difference between the speed of the machine and the synchronous speed (the slip). At standstill, the frequency will be the same as the frequency in the stator; the voltage is determined by the ratio of the stator and rotor winding turns. Thus if the number of turns is equal, the rotor has the same voltage as the stator. The doubly-fed machine is a transformer at standstill. The transformer-like characteristics are also present when it is rotating, manifesting itself especially during transients in the grid.

Due to the voltage and current behavior described above the rotor will either require, or generate, active power depending on the speed and torque. If the machine is producing torque and operating as a motor, the rotor will generate power if the speed is below synchronous speed (subsynchronous operation). At standstill all power fed in the stator (excluding losses) is returned via the rotor. The magnitude of the active power depends on the torque of the motor. Thus if the motor has rated torque, rated power is circulating through the stator and rotor. Like all electric machines, the efficiency of the machine is not very good at low speeds because current is required to produce torque but little or no mechanical power is produced.

If the machine is operating as a motor at speeds over the synchronous speed (supersynchronous operation), the mechanical power is fed in both through the stator and rotor. As a consequence the efficiency is now better than with singly fed motors. For example, at maximum speed the doubly-fed electric machine with equal stator and rotor turns produces same torque at double speed (and thus twice the power) as a singly-fed electric machine. The losses, being roughly proportional to the torque, are quite the same. Thus efficiency, which is the power taken divided by the produced power, is better than singly-fed electric machines. Naturally one has to take into account the loss of the power electronic control equipment. However, the frequency converter of the doubly fed machine has to control only 50% or less of the power of the machine, and thus has about half of the loss of the singly-fed machines' frequency converter that has to pass through 100 % of the power.

Since efficiency is the ratio between the output power (i.e., input power minus the loss) to the input power, the magnetic core efficiency of a wound rotor doubly fed machine, which has just two winding sets (i.e., dual armature winding sets) of loss but shows twice the power for a given frequency and voltage of operation, is comparable to the magnetic core efficiency of permanent magnet machines with just one winding set (i.e., single armature winding set) of loss but without magnetizing current. Coupled with the low power electronic controller, the wound-rotor doubly-fed electric machine system would be more efficient than permanent magnet machine systems without magnetizing current.

For operation as a generator a similar situation exists. At subsynchronous speeds the stator is generating the power but part of it has to be fed back to rotor. At supersynchronous speeds both the rotor and stator are producing power to the grid.

Thus the current rating of the rotor converter is defined by the maximum active current required by the torque production and the maximum reactive current required to magnetize the machine.

Doubly-fed electric machines outperform the others in supersynchronous speeds. They can operate at constant torque to twice synchronous speed if each active winding is rated at half the total power of the machine (i.e., contiguous operation between sub-synchronous through supersynchronous speed range).

It is important to note, however, that doubly fed machines do not produce more rated torque per volume than singly fed machines. The bigger power rating is due to the higher speed attainable without weakening the magnetic flux. The short time maximum torque of a wound rotor doubly fed machine is, however, much higher than with ordinary induction or permanent magnet machines, which experience core saturation, and in practice limited only by the temperature of the windings and the maximum current capability of the rotor frequency converter.

With one of the two armature winding sets (i.e., doubly fed) residing on the rotor and stator body, respectively, the rotor real estate of the wound-rotor doubly fed machine actively participates in the energy conversion process, which is different from all other electric machines, including permanent magnet synchronous machines. As a result, the magnetic core of the wound-rotor doubly fed electric machine shows highest power density.

Changing of the direction of the rotation requires the swap of two stator phases near zero speed if symmetrical speed range in both directions is required.

Further note, it is common to dimension the doubly fed machine to operate only at a narrow speed range around synchronous speed and thus further decrease the power rating (and cost) of the frequency converter in the rotor circuit.

Typical applications of doubly fed machines have been high power pumps and fans, hydro and wind generators, shaft generators for ships etc. where operating speed range has been quite narrow, less than ± 30 % of the synchronous speed and only small power is required in the subsynchronous range.

Due to the high rotor to stator winding turn ratio and the high voltage thus induced in the rotor at standstill, the starting of this kind of restricted operating speed range motor drive is usually done with rotor resistors in induction motor mode. When speed is in the operating speed range, the resistors are disconnected and the frequency converter is connected to the rotor. It is also possible to short circuit the stator and use the frequency converter in the induction motor control mode to accelerate the motor to the operating speed range. Generators, naturally, don't usually need any additional starting means because wind or water is used to accelerate the machine to the operating speed range.

Electronic control

The electronic controller, a frequency converter, conditions bi-directional (i.e., four quadrant), speed synchronized, and multiphase electrical power to at least one of the winding sets (generally, the rotor winding set). Using four quadrant control, which must be continuously stable throughout the speed range, a wound-rotor doubly-fed electric machine with two poles (i.e., one pole-pair) has a constant torque speed range of 7200 rpm when operating at 60 Hz. However, in high power applications two or three pole-pair machines with respectively lower maximum speeds are common.

The electronic controller is smaller, less expensive, more efficient, and more compact than electronic controllers of singly-fed electric machine because in the simplest configuration, only the power of the rotating (or moving) active winding set is controlled, which is less than half the total power output of the electric machine.

Due to the lack of damper windings used in synchronous machines, the doubly fed electric machines are susceptible to instability without stabilizing control. Like any synchronous machine, losing synchronism will result in alternating torque pulsation and other related consequences.

Doubly-fed electric machines require electronic control for practical operation and should be considered an electric machine system or more appropriately, an adjustable-speed drive.

Wound-rotor doubly-fed electric machine

Construction

Two multiphase winding sets with similar pole-pairs are placed on the rotor and stator bodies, respectively. The wound-rotor doubly-fed electric machine is the only electric machine with two independent active winding sets, the rotor and stator winding sets, occupying the same core volume as other electric machines. Since the rotor winding set actively participates in the energy conversion process with the stator winding set, utilization of the magnetic core real estate is optimized.

The doubly fed machine operation at unity stator power factor requires higher flux in the air-gap of the machine than when the machine is used as wound rotor induction machine. It is quite common that wound rotor machines not designed to doubly fed operation saturate heavily if doubly fed operation at rated stator voltage is attempted. Thus a special design for doubly fed operation is necessary.

A multiphase slip ring assembly (i.e., sliding electrical contacts) is traditionally used to transfer power to the rotating (moving) winding set and to allow independent control of the rotor winding set. The slip ring assembly requires maintenance and compromises system reliability, cost and efficiency. Attempts to avoid the slip ring assembly are constantly being researched with limited success (see Brushless doubly-fed induction electric machines).

Control

Although the multiphase slip ring assembly compromises core real estate, reliability, cost, and efficiency, it allows independent electronic control of the rotor (moving) winding set so both multiphase winding sets actively participate in the energy conversion process with the electronic controller controlling half (or less) of the power capacity of the electric machine for full control of the machine.

This is especially important when operating at synchronous speed, because then the rotor current will be DC current. Without slip rings the production of DC current in the rotor winding is only possible when the frequency converter is at least partly located in the rotor and rotating with it. This kind of rotor converter naturally requires own winding system (preferably using high frequency in the 10 kHz range for compact size) for power transfer out of or into the rotor. However, this kind of arrangement may have higher cost and lower efficiency than the slip ring alternative due to multiple power conversions and the thermal and mechanical constraints (for example centrifugal forces) of the power electronic assembly in the rotor. However, electronics have been incorporated on the rotor for many years (i.e., high speed alternators with brushless field exciters) for the improved reliability. Furthermore, high frequency power transfer is used in many applications because of improvements in efficiency and cost over low frequency alternatives, such as the DC link chokes and capacitors in traditional electronic controllers.

Efficiency

Neglecting the slip ring assembly, the theoretical electrical loss of the wound-rotor doubly-fed machine in supersynchronous operation is comparable to the most efficient electric machine systems available (i.e., the synchronous electric machine with permanent magnet assembly) with similar operating metrics because the total current is split between the rotor and stator winding sets while the electrical loss of the winding set is proportional to the square product of the current flowing through the winding set. Further considering the electronic controller conditions less than 50% of the power of the machine, the wound-rotor doubly-fed electric motor or generator (without brushes and with stable control at any speed) theoretically shows nearly half the electrical loss (i.e., winding set loss) of other electric motor or generator systems of similar rating.

Power density

Neglecting the slip ring assembly and considering similar air-gap flux density, the physical size of the magnetic core of the wound-rotor doubly-fed electric machine is smaller than other electric machines because the two active winding sets are individually placed on the rotor and stator bodies, respectively, with virtually no real-estate penalty. In all other electric machines, the rotor assembly is passive real estate that does not actively contribute to power production. The potential of higher speed for a given frequency of excitation, alone, is an indication of higher power density potential. The constant-torque speed range is up to 7200 rpm @ 60 Hz with 2 poles compared to 3600 rpm @ 60 Hz with 2 poles for other electric machines. In theory, the core volume is nearly half the physical size (i.e., winding set loss) of other electric motor or generator systems of similar rating.

Cost

Neglecting the slip ring assembly, the theoretical system cost is nearly 50% less than other machines of similar rating because the power rating of the electronic controller, which is the significant cost of any electric machine system, is 50% (or less) than other electric motor or generator systems of similar rating.

Double fed induction generator

DFIG is an abbreviation for Double Fed Induction Generator, a generating principle widely used in wind turbines. It is based on an induction generator with a multiphase wound rotor and a multiphase slip ring assembly with brushes for access to the rotor windings. It is possible to avoid the multiphase slip ring assembly (see brushless doubly-fed electric machines), but there are problems with efficiency, cost and size. A better alternative is a brushless wound-rotor doubly-fed electric machine.

File:Generator principle of DFIG.jpg
Principle of a Double Fed Induction Generator connected to a wind turbine

The principle of the DFIG is that rotor windings are connected to the grid via slip rings and back-to-back voltage source converter that controls both the rotor and the grid currents. Thus rotor frequency can freely differ from the grid frequency (50 or 60 Hz). By using the converter to control the rotor currents, it is possible to adjust the active and reactive power fed to the grid from the stator independently of the generator's turning speed. The control principle used is either the two-axis current vector control or direct torque control (DTC) [1]. DTC has turned out to have better stability than current vector control especially when high reactive currents are required from the generator.[2]

The doubly-fed generator rotors are typically wound with 2 to 3 times the number of turns of the stator. This means that the rotor voltages will be higher and currents respectively lower. Thus in the typical ± 30 % operational speed range around the synchronous speed, the rated current of the converter is accordingly lower which leads to a lower cost of the converter. The drawback is that controlled operation outside the operational speed range is impossible because of the higher than rated rotor voltage. Further, the voltage transients due to the grid disturbances (three- and two-phase voltage dips, especially) will also be magnified. In order to prevent high rotor voltages - and high currents resulting from these voltages - from destroying the IGBTs and diodes of the converter, a protection circuit (called crowbar) is used.

The crowbar will short-circuit the rotor windings through a small resistance when excessive currents or voltages are detected. In order to be able to continue the operation as quickly as possible an active crowbar[3] has to be used. The active crowbar can remove the rotor short in a controlled way and thus the rotor side converter can be started only after 20-60 ms from the start of the grid disturbance. Thus it is possible to generate reactive current to the grid during the rest of the voltage dip and in this way help the grid to recover from the fault.

As a summary, a doubly fed induction machine is a wound-rotor doubly-fed electric machine and has several advantages over a conventional induction machine in wind power applications. First, as the rotor circuit is controlled by a power electronics converter, the induction generator is able to both import and export reactive power. This has important consequences for power system stability and allows the machine to support the grid during severe voltage disturbances (low voltage ride through, LVRT). Second, the control of the rotor voltages and currents enables the induction machine to remain synchronized with the grid while the wind turbine speed varies. A variable speed wind turbine utilizes the available wind resource more efficiently than a fixed speed wind turbine, especially during light wind conditions. Third, the cost of the converter is low when compared with other variable speed solutions because only a fraction of the mechanical power, typically 25-30 %, is fed to the grid through the converter, the rest being fed to grid directly from the stator. The efficiency of the DFIG is very good for the same reason.

Brushless doubly-fed versions

Brushless doubly-fed induction electric machines

Brushless doubly-fed induction electric machines (i.e., electric motors or electric generators) are constructed by adjacently placing two multiphase winding sets with unlike pole-pairs on the stator body. With unlike pole-pairs between the two winding sets, low frequency magnetic induction is assured over the speed range. One of the stator winding sets (power winding) is connected to the grid and the other winding set (control winding) is supplied from a frequency converter. The shaft speed is adjusted by varying the frequency of the control winding. As a doubly-fed electric machine, the rating of the frequency converter need only be fraction of the machine rating.

The brushless doubly-fed electric machine does not utilize core real-estate efficiently and the dual winding set stator assembly is physically larger than other electric machines of comparable power rating. In addition, a specially designed rotor assembly tries to focus most of the mutual magnetic field to follow an indirect path across the air-gap and through the rotor assembly for inductive coupling (i.e., brushless) between the two adjacent winding sets. As a result, the adjacent winding sets are excited independently and actively participate in the electro-mechanical energy conversion process, which is a criterion of doubly-fed electric machines.

The type of rotor assembly determines if the machine is a reluctance or induction doubly-fed electric machine. The constant torque speed range is always less than 1800 rpm @ 60 Hz because the effective pole count is the average of the unlike pole-pairs of the two active winding sets. Brushless doubly-fed electric machines incorporate a poor electromagnetic design that compromises physical size, cost, and electrical efficiency, to chiefly avoid a multiphase slip ring assembly. Although brushless doubly-fed electric machines have not seen commercial success since their conception in the early 1970s, the promise of a low cost, highly efficient electronic controller keeps the concept under perpetual study, research, and development.

Brushless wound-rotor doubly-fed electric machine

The brushless wound-rotor doubly-fed electric machine (i.e., electric motor or electric generator) incorporates the electromagnetic structure of the wound-rotor doubly-fed electric machine, but replaces the traditional multiphase slip ring assembly with a brushless means to independently power the rotor winding set (i.e., doubly-fed) with multiphase AC power. The torque of the wound-rotor doubly-fed electric machine is dependent on both slip and position, which is a classic condition for instability. For stable operation, the frequency and phase of the multiphase AC power must be synchronized and fixed instantaneously to the speed and position of the shaft, which is not trivial at any speed and particularly difficult about synchronous speed where induction no longer exists. If these conditions are met, all the attractive attributes of the wound-rotor doubly-fed electric machine, such as high power density, low cost, ultra-high efficiency, and ultra-high torque potential, are realized without the traditional slip-ring assembly and instability problems.[4] One company,[5] has patented and is selling a brushless, fully stable, synchronous wound-rotor doubly-fed electric machine with symmetric quality of motoring or generating. Another brushless wound-rotor construction invented by Lars Gertmar has been described in the patent application.[6]

See also

References

Cite error: Invalid <references> tag; parameter "group" is allowed only.

Use <references />, or <references group="..." />
de:Doppelt gespeiste Asynchronmaschine fr:Cascade hyposynchrone
  1. U.S. Patent 6,448,735
  2. About the active and reactive power measurements in unsymmetrical voltage dip ride through testing at Nordic Wind Power Conference 2006.
  3. an active crowbar: for example U.S. Patent 7,164,562
  4. FAQ: Advanced Brushless Wound-rotor Synchronous Doubly-fed Electric Motor Or Generator System (Bwrsdfs)
  5. Best Electric Machine
  6. Power Converter With Rotating/Stationary Communication/Processing Means at the European Patent Office (in Swedish).